Product Description
Specifications
- LS Electric
 
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter
 
- LSLV-S100 series
 
- (input) 50/60 Hz
 
- (output) 0-400 Hz
 
- (output; IM sensorless) 0-120 Hz
 
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter
 - V/f control
 - Sensorless vector control
 - Manual/Automatic torque boost
 - PID control
 - Up-Down operation
 - 3-wire operation
 - DC braking
 - Frequency limit
 - Frequency jump
 - 2nd function
 - Slip compensation
 - Anti reverse rotation
 - Automatic restart
 - Commercial power change
 - Auto-tuning
 - Flying start
 - Energy buffering operation
 - Power braking
 - Flux braking
 - Leakage reduction operation
 
Design
- Single-phase 200V class
 - Frame size 7
 - heatsink out the back
 
- 200Vac-240Vac (3-phase) (-15%...+10%) (208Vac / 220Vac / 230Vac)
 
- built-in LED 4-digit keypad display
 
- 18A (normal duty)
 - 17A (heavy duty)
 
- 5.5kW (normal duty)
 - 4kW (heavy duty)
 
- 7.5HP / 7-1/2HP (normal duty)
 - 5.5HP / 5-1/2HP (heavy duty)
 
- Overcurrent
 - Overvoltage
 - Undervoltage
 - External trip
 - Ground fault current detection
 - Drive / Motor overheat
 - Input-Output phase open
 - Overload protection
 - Light load protection
 - Communication error
 - Frequency command loss
 - Hardware fault
 - Cooling fan fault
 - Pre-PID motion failure
 - No motor trip
 - External brake trip
 - Option fault
 - Safety contact fault
 - Drive temperature sensor fault
 - Parameter write error
 - IO board fault
 
- RS-485
 
- 4 x digital inputs (24Vdc; NPN/Sink or PNP/Source) (FX Forward; RX Reverse; BX Emergency stop; RST Reset)
 - 1 x digital input (12Vdc; Pulse train 0-32kHz or Speed preset)
 
- 2 x digital inputs (Safe-Torque OFF STO A and B)
 - 1 x digital output (SPDT Form-C NO/NC rly. contact; C1; A1; B1; 1A at 250Vac/30Vdc)
 - 1 x digital output (open-collector; pulse train output 32kHz / PTO frequency or RUN status)
 
- 1 x analog input (-10...+10Vdc / 0-10Vdc / 4-20mA)
 
- 1 x analog outputs (0-12Vdc / 0-20mA)
 
- IP20
 - NEMA 1
 
- W5.5" x H5" x D5.7"
 
- -10...+50 °C
 
- 6.9kVA (normal duty)
 - 6.5kVA (heavy duty)
 
- Applied to the industries such as metal; elevator/escalator; textile machinery; shipping; food and beverage; pulp/paper; coal mine; oil/gas and water treatment
 
- 6030000600
 
- CE
 - cULus
 
- Accurate velocity and torque operation
 - Reduced installation area; and when multiple drives are installed; the control panel size is significantly reduced
 - Possible to connect to all widely-used field networks; comfortable maintenance of option cards and easy mounting
 - High-level control programming with only the drive and without the external PLC
 - Improved power factor and THD reduction
 - Satisfied the safety standards of systems with a built-in safety design
 - Reduced electromagnetic noise; additional space and expense for parts not required