BRK 1010B Photoelectric Smoke Alarm 120V AC/DC w/Battery Backup

Hover over image to zoom

  • BRK 1010B Photoelectric Smoke Alarm 120V AC/DC w/Battery Backup
  • BRK 1010B Photoelectric Smoke Alarm 120V AC/DC w/Battery Backup
$20.55
SKU:
7010B
UPC:
029054112019
Shipping Cost:
Calculated by weight at checkout.
Minimum Purchase:
1 unit(s)

 Product Description

BRK 1010B Photoelectric Smoke Alarm 120V AC/DC w/Battery Backup

Hardwired smoke alarm with battery back-up meets codes where a photoelectric smoke sensor is required for new construction.

Recommended for installation outside areas that are prone to nuisance alarms such as kitchens, bathrooms and utility rooms.

» Photoelectric smoke sensing technology

» Latching Alarm Indicator (on product made after June 2010)

» Single button test/silence

» 9V Battery Backup

» Optipath 360 TechnologyTM - patented technology provides 360 degrees of direct access to the smoke sensor.

» Perfect Mount - allows for easy alignment of alarm

» Dust Cover

» Easy Installation/Maintenance - Preferred features include a large opening in the mounting bracket for easy access to wiring. Keyhole slots in the mounting bracket eliminate the need to remove the electrical box screws for installation. A battery pull tab keeps the battery fresh until the home is occupied. Battery installation and removal can occur while the unit is mounted to the ceiling or wall via the side load battery compartment. Two locking features are provided to prevent battery theft and/or theft of the unit. Connection to AC power is made with a "Quick-Connect" wiring harness. Installation is quick, easy and cost effective.

» 10-Year Limited Warranty

TECHNICAL SPECS

  • Alarm Dimensions:  5.0”Dia. x 2.1”H
  • Weight:  8.4 oz
  • Operating Voltage:  120V AC 60Hz w/ 9V battery backup
  • Temperature Range:  40°F (4°C) to 100°F (38°C)
  • Humidity Range:10% to 95% relative humidity (RH)
  • Audio Alarm:85dB at 10 feet
  • Test/Silence:Electronically simulates smoke condition,  causing the  unit to alarm. Press and hold test/silence button.
  • Alarm Reset:Automatic when smoke clears
  • Interconnections:Up to 18 units of First Alert or BRK Smoke, CO and Heat  Alarms. Maximum of 12 smoke alarms. See user’smanual for details.
  • Smoke Sensor:Photoelectric
  • Indicator Lights/Sounds: 

               - AC Power:  Constant Green LED  
               - DC Power:  Intermittent Red LED  
               - Local Alarm:  Red LED flashes rapidly  
               - Latching Alarm:  Red LED flashes once per second for 3 seconds afterlocal alarm. Pattern repeats approximately every 45 secs.  
               - Remote Alarm:  Audio alarm and Red LED out.

  • Listing:Listed to UL217 Standard

ARCHITECTUAL AND ENGINEERING SPECIFICATIONS

The smoke alarm shall be BRK Model 7010B or approved equal and shall provide, at a minimum, the following features and functions.

1.    A photoelectric sensing chamber.
2.    The unit shall be capable of self restoring.
3.    A screened sensing chamber to prevent entry of small insects thereby reducing the probability of unwanted nuisance alarms.
4.    Powered by 120V AC, 60Hz and have a monitored 9V battery backup.
5.    A visual LED (green) power-on indicator to confirm unit is receiving power. A visual LED (red) indicator to confirm unit has switched to battery backup mode or is in alarm.
6.    A single button test/silence feature. Test button should check all alarm functions by simulating a smoke condition, causing the unit to alarm. The silence feature to temporarily silence unwanted alarms.
7.    A solid state piezo horn rated at 85dB minimum at 10 ft.
8.    The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 90%.
9.    The unit shall center mount to any standard electrical junction box up to 4 inches octagonal without screw removal and shall be listed for wall or ceiling mounting.
10.    The unit shall have a locking mechanism to deter battery removal and /or theft of the unit.
11.    The unit shall have a gasketless base for easy installation and be capable of keeping alarm secure over a wide rotation range to allow for true alarm alignment.
12.    The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms, 12 of which can be smoke alarms.
13.    A dust cover shall be provided to keep alarm clean during construction.
14.    The unit shall at a minimum meet the requirements of UL217, CSFM, NFPA 72, NFPA 101, ICC, ICBO, BOCA, SBCCI and CABO.

 

 Find Similar Products by Category

 Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Condition: New In stock

You Recently Viewed...

 

What's News

Follow us on


payment logos

Copyright 2019 Galesburg Electric/Industrial Supply, Inc.. All Rights Reserved.
 Sitemap |


739 South Henderson Street, Galesburg, IL 61401
Toll Free 1-877-552-8036 International 1-309-343-4138
Business hours: Monday - Friday 8am to 5pm, Saturday 8am to 12pm

Click the button below to add the BRK 1010B Photoelectric Smoke Alarm 120V AC/DC w/Battery Backup to your wish list.