Description |
The FireX 484 is a photoelectric smoke alarm. This unit has
an 85 decibel horn, test switch, and lighted power/alarm LED indicators. The
484 AC smoke alarm can be interconnected with FireX ionization as well as
photoelectric smoke alarms for the best smoke detection system.
| 484 |
120V AC Direct Wire for
single or multiple station use. The 484 is interconnectable up to 18
Firex AC smoke alarms. A green lighted LED "blinks" once per minute to
confirm constant AC power and once per second when in alarm. |
These FireX
smoke alarms should be placed in single-family households or in each
individual living unit of multiple-family buildings. All smoke alarms
should be replaced every 10 years. |
|
Features and Benefits |
Advanced
photoelectric design
— Fast detection
of slow smoldering fires.
Installation design and features similar to other FireX smoke alarms
— Contractor familiarity with installation
Interconnects with FireX ionization and photoelectric smoke alarms
— Compatible with other contractor preferred FireX products
Lighted Power/Alarm LED — Confirms unit is receiving power and
provides visual indication of initiating alarm in interconnected systems
Incorporates FireX installer-focused innovations — Fastest and
easiest installation available
Factory sealed housing — Prevents tampering and provides
outstanding durability. |
|
Why
Install a FireX Photoelectric Smoke Alarm? |
|
FireX photoelectric
smoke alarms respond to slow burning, visible smoke caused by smoldering
fires. Designed for use in kitchens and furnace rooms, they reduce nuisance
caused by cooking fumes or high humidity. With installer focused innovations
such as gasketless mounting, separate mounting bracket as well as
state-of-the-art production testing equipment, FireX photoelectric smoke
alarms have earned their reputation as the most preferred smoke alarms among
contractors. |
|
Architectural Specifications |
|
The 484(C) shall be
1-3/16" high and 4-7/8" wide powered by a 120V AC, 60Hz source. Nominal
sensitivity shall be measured by U.L. at obs. 2.2± 1.2%/ft. and by U.L.C. at
obs. 2.2± .75%/ft. A power-on indicator shall be a built-in LED which blinks
once per minute in the standby condition; when activated, the initiating
alarm LED shall flash while the interconnected alarms remain extinguished.
All FireX
photoelectric smoke alarm shall be a Styleline design™ and have a
photoelectric sensor. operating temperature range shall be between 40° and
100°F(4°-38°C) and relative humidity shall range between 10%-93%. The test
switch shall electronically activate the chamber to simulate smoke and check
for proper operation. The electric horn shall have a level of 85 decibels at
10 feet and all units have a separate mounting bracket. |
|
Technical Specifications |
|
Item |
484(C) |
| Model |
PG |
|
Product Weight |
5.5 ounces |
|
Operating Temperature |
40°-100°F
4°-38°C |
|
Electrical Rating |
120V AC, 60Hz,
50mA |
Alarm
Point
(Canadian) |
obs. 2.2±
1.2%/ft.
( obs. 2.2± .75%/ft.) |
| Horn
Output |
85 decibels at
10 feet |
| Listing |
UL 217 and ULC
S531 |
| Detection
Type |
Photoelectric
Chamber |
| Humidity
Rating |
10%-93% |
|
|
Interconnect Quantities |
|
484 |
| Item(
Model) |
484
(PG) |
406
(G) |
418
(G) |
41216
(GC) |
| Quantity |
<
18 |
<
6 |
<
18 |
<
18 |
|