Description |
The Firex 4480 are photoelectric smoke alarms. These units
have an 85 decibel horn, test switch, and lighted power/alarm LED
indicators. The 4480 smoke alarms can be interconnected with Firex
ionization as well as photoelectric smoke alarms for the best smoke
detection system.
| 4480 |
120V AC Direct Wire with Battery Back-up
for single or multiple station use. The 4480 is interconnectable up to
18 Firex AC/DC units, 6 of which may be Firex heat alarms. This unit has
two separate lighted LEDs — green "power-on" LED confirms constant AC
power and the red LED displays alarm/battery status. |
These FireX
smoke alarms should be placed in single-family households or in each
individual living unit of multiple-family buildings. All smoke alarms
should be replaced every 10 years. |
|
Features and Benefits |
Advanced
photoelectric design
— Fast detection
of slow smoldering fires.
Installation design and features similar to other Firex smoke alarms
— Contractor familiarity with installation
Interconnects with Firex ionization and photoelectric smoke alarms —
Compatible with other contractor preferred Firex products
Interconnects with Firex heat alarms — Item 4480 interconnects
with the Firex heat alarm for a complete smoke and fire detection system
Lighted Power/Alarm LED — Confirms unit is receiving power and
provides visual indication of initiating alarm in interconnected systems
Incorporates Firex installer-focused innovations — Fastest and
easiest installation available
Factory sealed housing — Prevents tampering and provides
outstanding durability. |
|
Why
Install a FireX Photoelectric Smoke Alarm? |
|
Firex photoelectric
smoke alarms respond to slow burning, visible smoke caused by smoldering
fires. Designed for use in kitchens and furnace rooms, they reduce nuisance
caused by cooking fumes or high humidity. With installer focused innovations
such as gasketless mounting, separate mounting bracket as well as
state-of-the-art production testing equipment, Firex photoelectric smoke
alarms have earned their reputation as the most preferred smoke alarms among
contractors. |
|
Architectural Specifications |
|
The 4480 shall be
1-3/8" high and 5" wide, powered by a 120V AC, 60Hz source with a 9 volt
battery back-up. Nominal sensitivity shall be measured by U.L. at obs
2.3±.95%/ft. A green continuous power on indicator shall be a built-in light
emitting diode (LED) in the standby condition; a second red blinking LED
shall indicate that a sufficient 9-volt battery back-up is present; when
activated, the initiating alarm red LED shall flash while the interconnected
alarms remain extinguished. A 70 day low battery signal shall be included. All FireX
photoelectric smoke alarm shall be a Styleline design™ and have a
photoelectric sensor. operating temperature range shall be between 40° and
100°F(4°-38°C) and relative humidity shall range between 10%-93%. The test
switch shall electronically activate the chamber to simulate smoke and check
for proper operation. The electric horn shall have a level of 85 decibels at
10 feet and all units have a separate mounting bracket. |
|
Technical Specifications |
|
Item |
4480 |
| Model |
PAD |
|
Product Weight |
8 ounces |
|
Operating Temperature |
40°-100°F
4°-38°C |
|
Electrical Rating |
120V AC, 60Hz,
50mA max, 9volt Battery Backup |
Alarm
Point
(Canadian) |
obs. 2.3±
.95%/ft.
N/A |
| Horn
Output |
85 decibels at
10 feet |
| Listing |
UL 217 and ULC
S531 |
| Detection
Type |
Photoelectric
Chamber |
| Humidity
Rating |
10%-93% |
|
|
Interconnect Quantities |
|
4480 |
| Item(
Model) |
4480
(PAD) |
4418
(AD) |
4518
(ADC) |
5700*
(ADH) |
| Quantity |
<
18 |
<
18 |
<
18 |
<
18 |
|