firex smoke alarms,baldor electric motors,drives,firex,smoke alarms,tools,smoke detector,heat alarm,hand power tools,crimp tool,cutter,ideal,milwaukee,makita,porter cable,delta,brady labels id pal,inverters,greenlee cutter kit,reconditioned tools,metabo tools,dewalt tools,Fluke,leviton,wiring devices,electical supplies,generac,guardian generators,powermatic,data commucication equipment,3M scotch tape,yamaha,telcom,klein tools,saw blades,GE,T&B,wire ties connectors,cable ties,Honeywell thermostat
Home
Store Map
Shopping Cart
Contact Us
Help
US TOLL FREE: 1-877-552-8036   International: 1-309-343-4138  
Fax: 1-309-343-4096
Tools: Ryan Scalf, Baldor Motors: Don Gillenwater, GE: Preston Johnson
  Search:      Advanced Search
Username Password
Log in    Register


 
     Categories
 
Baldor Reliance Motors & DC Controls
 
Conduit & Fittings
 
Electric Heat & Ventilation
 
Electrical
 
Fasteners
 
Light Bulbs
 
Literature
 
Material, Repair & Operation
 
Miscellaneous
 
Motor Controls
 
Product Lists
 
Repair Parts
 
Safety & Security
 
Service Entrance Equipment
 
Smoke & CO Alarms
 
Tape
 
Test Equipment
 
Tools
 
Wire
 
Work Gloves


     Special
Gift certificates


     Help
Contact us
Privacy statement
Terms & Conditions/Shipping
About Us
Product Lines
Security
Testimonials




  Galesburg Electric/Industrial Supply, Inc. -- A Globally Recognized Distributor :: Safety & Security :: Smoke & CO Alarms :: FireX 428 FXW-R - Smoke Alarm 120V AC Direct Wire

  FireX 428 FXW-R - Smoke Alarm 120V AC Direct Wire #499
FireX 428 FXW-R - Smoke Alarm 120V AC Direct Wire 
Detailed Image

FireX 428 FXW-R - Smoke Alarm 120V AC Direct Wire

Description
The Firex 406, 428 and 41216 smoke alarms are ionization 120 V AC smoke alarms. These units have an 85 decibel horn, test switch and lighted power/alarm LED indicator; the LED flashes once per minute to confirm AC power. When in alarm, the LED flashes rapidly once per second. when interconnected with other Firex smoke alarms, the unit that initiates an alarm will display the rapidly flashing LED while the other interconnected alarm LEDs will remain extinguished. The 41216 includes a False Alarm Control™ feature which allows the user to quiet an unwanted alarm for up to 15 minutes.

These units mount to any single or 4" octagon junction box or square-to-round drywall ring and has 8" long pigtails with a Quick Connect harness for permanent connection. Firex AC smoke alarms are for single or multiple station use and interconnect with other Firex smoke alarms (see Technical Specifications below for interconnect quantities and compatibility). This Firex should be placed in single-family households or in each individual living unit of multiple-family buildings.

Features and Benefits
Dual ionization smoke sensing chamber early detection of fast burning fires such as gasoline, cooking grease and paper.
Installation design and features similar to other Firex smoke alarms Contractor familiarity with installation
Interconnect Flexibility Product line offers contractors the right number of interconnects for their application
Lighted Power/Alarm LED Confirms unit is receiving power and provides visual indication of initiating alarm in interconnected systems
Incorporates Firex installer-focused innovations Fastest and easiest installation available
Factory sealed housing Prevents tampering and provides outstanding durability.
False Alarm Control™  (item41216 only) - Quiets unwanted alarms for up to 15 minutes
Why Install a Firex AC ionization Smoke Alarm?
Firex AC ionization smoke alarms provide contractors and homeowners with reliable and trouble-free performance they expect from Firex... the market leader in fire safety products. They meet building code requirements where AC smoke alarms with interconnectability for up to 120 stations. with installer-focused innovations such as "Quick Connect", gasketless mounting as well as state-of-the-art production testing equipment, Firex AC ionization smoke alarms have earned their reputation as the most preferred smoke alarms among contractors.
Architectural Specifications
The smoke alarm shall be a Styleline design™ (1-3/16" high, 4-7/8" wide), powered by a 120 VAC, 60Hz source with a dual chamber ionization sensor. the alarm shall be rated at no greater than 0.5W (0.9W for the 428) in standby. Nominal sensitivity shall be measured by U.L. at obs. 1.1± 0.47%/ft. and by U.L.C. at 1.1%. Temperature operating range shall be between 40° and 100°F (4°-38°C); humidity range between 10%-93% relative humidity; 1005 solid state alarm circuits over an input range of 100-300 VAC. A power-on indicator shall be built-in lighting emitting diode which "blinks" once per minute in the standby condition. the test switch shall electronically activate the chamber to simulate smoke and check for proper operation.  The electronic horn shall have a level of 85 decibels at 10 ft. the alarm shall mount to a single gang box 4" octagon junction box, or a square to round drywall ring without screw removal. It shall have a pigtail wiring, "Quick Connect" molded harness, separate mounting bracket. The False Alarm Control™ feature on the 41216 shall desensitize the alarm for 15 minutes. The red LED shall blink once every 10 seconds when in False Alarm Control™ and the alarm shall produce two short chirps 2 seconds apart at the conclusion of the desensitized period. See Technical specifications for interconnectable quantities. The alarm shall have an Interconnect Protection Feature that prevents "blown" circuitry in the initiating alarm if the number of interconnected alarms is greater than the maximum limit. The 406, 428, 41216 shall meet the requirements of U.L. standard 217 and the 406(C), 428(C) shall meet the requirements of U.L.C. Standard S531.
 
Technical Specifications
Items 421(C), 406(C),428(C), 41216
Model G (GC for item 41216), (H for item 421), (FXW-R for item 428)
Product Weight

5.5 ounces

Operating Temperature

40°-100°F     4°-38°C

Interconnect Quantity 418C-18
428/428C-18*
406/406C-6
41216-18
Electrical Rating

120V AC, 60Hz, 50mA max

Alarm Point

obs. 1.1±0.47%/ft.

Horn Output

85 decibels at 10 feet

Listing

UL 217 and U.L.C. S531

Detection Type

Dual Ionization Chamber

Humidity Rating

10%-93% Relative Humidity

*Item 428 is a direct replacement for model FX 1014 single station and can replace and be interconnected with models FX 1020, FX 1106, and FXW-1A.

 

Installation of Smoke Alarm
This smoke alarm should be installed in accordance with NFPA's Standard 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA  02269) and any local codes that apply. For the AC and AC/DC direct wire smoke alarms use 18# AWG minimum solid or strand wire. When interconnecting , maximum wire length between any two is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance). DO NOT connect to any other type or model of heat or smoke alarm. Connect smoke and heat alarms to a single AC branch circuit. If local codes do not permit, be sure the neutral wire is common to both phases.

Details
 
Price: $11.20

Options
 
Quantity

 Add to cart 
        
 Shipping calculator 
        

 
 
FireX 428 FXW-R - Smoke Alarm 120V AC

  Send to friend
Your name: *
Your e-mail: *
Recipient's e-mail: *

 Send to friend 
 
  Customers' rating
Customers' rating

Customers' rating


Customer's voting

 


Customer's Reviews

Author: Unknown


 

Baldor Reliance Motors & DC Controls | Conduit & Fittings | Electric Heat & Ventilation | Electrical | Fasteners | Light Bulbs | Literature | Material, Repair & Operation | Miscellaneous | Motor Controls | Product Lists | Repair Parts | Safety & Security | Service Entrance Equipment | Smoke & CO Alarms | Tape | Test Equipment | Tools | Wire | Work Gloves | Help | Store Map

 
 
     Your cart
Cart is empty

View cart
Checkout

Internet Security By ControlScan Internet Security By ControlScan Internet Security By ControlScan

GalesburgElectric.com is a Better Business Bureau Member


     News
Galesburg Electric Lighting.com!! Offering the latest in Decorative Lighting, Ceiling Fans, Outdoor Lighting and much much more!

Galesburg Electric News!
Providing you the lastest news in the electrical & industrial industry. Click Here!


Curious about our service and products? See what others are saying about us!Click here

Quantity discounts are avaliable please contact us for more information.

Subscribe to our newsletter using the form below.

Your email:

Subscribe 




 
Payments we accept


Product pricing & availability is subject to change without notice.


Can't find the item you need?
We can get it for the lowest prices available--contact us for pricing and availability!

Contact us here

Galesburg Electric/Industrial Supply, Inc.

739 S. Henderson St. | Galesburg | IL | 61401 | PHONE: 1.877.552.8036 (U.S. only) | PHONE:1.309.343.4138 | FAX: 1.309.343.4096

Baldor Motors attn: Don Gillenwater Tools attn: Ryan Scalf Commercial Lighting attn: Craig Johnson GE attn: Preston Johnson

   Ecommerce solution by FINESTSHOPS Copyright © 1953-2008 Galesburg Electric/Industrial Supply, Inc. -- A Globally Recognized Distributor